Balancing General View Screen¶
Balancing General View Screen – Main View¶
This screen displays the statuses and movements of the motors that move the masses used for the fine balancing of the elevation axis, and enables their control.

Figure 2‑54. Balancing general view screen - main view.
ITEM |
DESCRIPTION |
|---|---|
1 |
Displays the status and position (in mm) of the motors. The box next to each motor lights up in the colour corresponding to its status. Displays the status of the limits of each motor. The box corresponding to the active limit lights up in green. Displays the graph with the real time torque of the elevation axis. Softkey “FREEZE GRAPH”: Freezes the graph. Softkey “UPDATE GRAPH”: Allows the graph to be updated after being frozen. |
2 |
Softkeys “90 X+”, “0 X+”, “90 X-” and “0 X-“: Select the balancing mass. Softkey “ALL”: Selects the four balancing masses. |
3 |
Softkey “ON”: Switches on the selected balancing mass, or all of them, depending on the selection. Softkey “OFF”: Switches off the selected balancing mass, or all of them, depending on the selection. Softkey “RESET ALARM”: Resets the selected balancing mass, or all of them, depending on the selection and resets the interlock if one exists. |
4 |
Only available when all axes are selected at the same time. Softkey “SIDE TO SIDE”: Moves all masses from side to side and returns them to the starting point. All masses move one at a time. Softkey “SAVE POS.”: Saves the current positions in the database. Softkey “MOVE TO SETTINGS”: Returns to the positions saved in the database. These values are shown in item 6 of this table. |
5 |
Adjusts the position (in deg) and speed (in deg/s) of the balancing motor, always individually. Softkeys “+” or “-”: Makes a movement at a constant speed in a positive or negative direction respectively. This sets the percentage of the default speed defined in the settings with the vertical slider. Softkey “MOVE”: Used to move the axes according to the previously entered specifications. Softkey “STOP”: Stop the movement of the axes. |
6 |
Displays the values saved in Settings |
7 |
Accesses the screen Locking Pins General View Displays the status of the locking pins and turns on the LED with the corresponding colour:
|
8 |
Displays the status and position (in deg) of “Elevation”. Accesses the screen Elevation General View |
9 |
The blue softkey navigates between the active interlocks, if there is more than one. When an interlock is active, the top box is displayed in red. If no interlocks are active, the box will be green and the blue softkey cannot be pressed. |
Balancing General View Screen – Current Move¶
This screen shows a graph of the movement of the four masses used to balance the elevation axis, in real time.

Figure 2‑55. Balancing general view screen - current move.
ITEM |
DESCRIPTION |
|---|---|
1 |
Shows the graph of the movement of the four masses used to balance the elevation axis, in real time. Softkey “FREEZE GRAPH”: Freezes the graph. Softkey “UPDATE GRAPH”: Allows the graph to be updated after being frozen. |
Balancing General View Screen – Move History¶
This screen displays and loads the last five movements of the masses used to balance the elevation axis, with number 1 being the last.

Figure 2‑56. Balancing general view screen - move history.
ITEM |
DESCRIPTION |
|---|---|
1 |
Softkey “LOAD”: Loads the last five movements. Once the desired movement has been selected, it allows it to be displayed on the graph. |
Getting out of a Software Limit Switch Interlock¶
When using the balancing system the software limit could be triggered.
Note that not all limit switches in the TMA go to the TMA interlock system (TMA IS), this is one of those which does not go to it.
For these balancing-related limit switches, they are not managed by the PXI code. So, they are not disabled in the TMA IS, they just prevent the movement in the drive. What the balancing software has are the software limits that will prevent motion out of the allowed range.
For example, the following screenshot shows the triggered software limit (negative position limit):

How to clear it:
Disable the negative software limit by going to the corresponding balancing settings window and selecting the correct instance:

Write to
FALSEthe corresponding limit positive/negative:
Go back to the balancing general view window and reset the interlock:

After the reset and power on the system:

Move into the range, the range can be checked in the settings of the corresponding instance (
Min PositionandMax Positionsettings):
Power off the system:

Restore the settings for enabling the limit again: