Encoder Settings Screen

This screen displays the list of encoder settings and allows their control.

Figure 2‑99. Encoder settings screen

ITEM

DESCRIPTION

1

Displays the list of encoder system parameters.

2

Changes the setting values of the different instances.

Drop down menu “Instance”: Selects the desired instance of the subsystem, in this case each head of the encoder.

Softkey “EXPORT”: Exports the data selected at the top.

Softkey “WRITE”: Applies the change made to a setting. The subsystem uses this value for the next start-up.

Softkey “RESTORE TEMPORARY”: Recovers the written values, i.e. those saved as “Write”.

Softkey “WRITE & SAFE”: Changes the modified settings (used by the subsystem) and permanently saves them in the database.

Softkey “RESTORE SAVED”: Recovers the permanent “Save” values from the database.