Encoder Settings Screen¶
This screen displays the list of encoder settings and allows their control.
Figure 2‑99. Encoder settings screen
ITEM |
DESCRIPTION |
---|---|
1 |
Displays the list of encoder system parameters. |
2 |
Changes the setting values of the different instances. Drop down menu “Instance”: Selects the desired instance of the subsystem, in this case each head of the encoder. Softkey “EXPORT”: Exports the data selected at the top. Softkey “WRITE”: Applies the change made to a setting. The subsystem uses this value for the next start-up. Softkey “RESTORE TEMPORARY”: Recovers the written values, i.e. those saved as “Write”. Softkey “WRITE & SAFE”: Changes the modified settings (used by the subsystem) and permanently saves them in the database. Softkey “RESTORE SAVED”: Recovers the permanent “Save” values from the database. |